Introducing the HP-7200smart Clamp Current Meter, a versatile and precise instrument designed for professionals and enthusiasts in the electrical and electronics fields. This True RMS 6000-count auto-ranging digital clamp meter offers a comprehensive set of features, making it an essential tool for accurate electrical measurements.
Product Specifications
Attribute | Details |
---|---|
Display Type | Digital Only |
Measuring Current Range | 0.15A–400A (AC) |
Measuring Voltage Range | 0.5V–600V (AC/DC) |
Measuring Resistance Range | 600Ω–60MΩ |
Measuring Capacitance Range | 6nF–60mF |
Dimensions | 207 mm × 75 mm × 37 mm |
Weight | 305 grams |
Operating Temperature | -10°C to 40°C |
Max. AC Voltage | 600V |
Max. DC Voltage | 600V |
Max. AC Current | 400A |
Safety Rating | CAT III 600V |
Key Features and Benefits
Feature | Benefit |
---|---|
Auto-Ranging Capability | Automatically selects the appropriate measurement range, simplifying operation and reducing the chance of errors. |
True RMS Measurement | Provides accurate readings for both sinusoidal and non-sinusoidal AC signals, essential for precise measurements in complex electrical environments. |
6000-Count Display | Offers high-resolution readings, enhancing measurement precision. |
Data Hold Function | Enables users to freeze the current reading on the display for convenient data recording. |
Max/Min Recording | Captures the maximum and minimum values during a measurement session, useful for analyzing fluctuations. |
Backlit LCD | Ensures clear visibility of readings in low-light conditions, improving usability in diverse environments. |
Non-Contact Voltage Detection (NCV) | Allows for the detection of live wires without direct contact, enhancing user safety. |
Continuity and Diode Testing | Facilitates quick checks of circuit continuity and diode functionality, aiding in troubleshooting. |
Overload Protection | Equipped with full-range overcurrent protection, enhancing safety and durability. |
Low Power Consumption | Designed for energy efficiency, extending battery life and reducing operational costs. |
Durable Construction | Built with high-quality materials, offering stability and resistance to drops, suitable for demanding work conditions. |
Applications
The HP-7200smart Clamp Current Meter is suitable for a wide range of applications, including:
Electrical Installations: Ideal for measuring current, voltage, and resistance in residential, commercial, and industrial electrical systems, ensuring compliance with safety standards.
Equipment Maintenance: Essential for troubleshooting and maintaining electrical equipment, identifying faults, and verifying proper operation.
Automotive Diagnostics: Useful for testing automotive electrical circuits, including battery health, alternator performance, and detecting parasitic drains.
HVAC Systems: Valuable for assessing the electrical components of heating, ventilation, and air conditioning systems, ensuring efficient and safe operation.
Educational Purposes: Serves as a practical tool for students and educators in electrical engineering and related fields, facilitating hands-on learning experiences.
How to Use the HP-7200smart Clamp Current Meter
Power On: Insert the appropriate batteries and press the power button to turn on the device.
Select Measurement Mode: Use the function selector dial to choose the desired measurement parameter (e.g., AC/DC current, voltage, resistance).
Auto-Ranging: The device will automatically select the appropriate range for the chosen measurement.
Clamp Measurement: For current measurements, open the jaw and enclose the conductor under test, ensuring it is centered within the clamp for accurate readings.
Probe Measurement: For voltage, resistance, capacitance, and other measurements, connect the test leads to the appropriate input terminals and contact the test points.
Read Measurements: Observe the readings on the backlit LCD. Utilize the data hold function if needed to freeze the displayed value.
Non-Contact Voltage Detection: Use the NCV function to detect live wires without direct contact by bringing the sensor close to the conductor.
Power Off: After use, turn off the device to conserve battery life.
Maintenance and Care
Regular Calibration: Periodically calibrate the device to maintain measurement accuracy.
Battery Replacement: Replace the batteries when the low battery indicator appears to ensure uninterrupted operation.
Proper Storage: Store the meter in a cool, dry place when not in use to protect it from environmental damage.
Cleaning: Clean the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents that may damage the surface or internal components.
Multimeter nearby, ac dc current clamp meter, clamp on smart water meter, dc voltage clamp meter, fluke clamp meter multimeter, clamp current meter
联系人:Ella Huang
手 机:+8613437856962
邮 箱:sales@lnalsafe.com
公 司:Guangzhou Mint machinery Equipment Co., LTD
地 址:Panyu District, Guangzhou City, Guangdong Province